Performance measurements from an industrial site fitted with the NEUTREC® process demonstrate how an installation can be easily adapted to changing emission limits.

The recordings reproduced below (carried out during 1998) relate to 12-hour periods with two different emission limits:

  • respecting an average HCl emission limit of 50 mg/Nm³ dry at 11 % O2
  • respecting an average HCl emission limit of 10 mg/Nm³ dry at 11 % O2

To move from the first to the second limit, all the operator had to do was to modify the parameters regulating the flow of bicarbonate. The flow was adapted automatically and no equipment needed to be modified.

 

Unit

Case 1:

'respect of 50 mg'

Case 2:

'respect of 10 mg'

Average HCl content

mg/Nm3 dry at 11% O2

45

9

Average sodium bicarbonate flowrate

kg/h

54

63

Average stoichiometric ratio

-

1.05

1.15



Case 1 : Respect of an emission limit of 50 mg HCl/Nm³ dry at 11% O2 (daily average)


Case 2:
 Respect of an emission limit of 10 mg HCl/Nm³ dry at 11% O2 (daily average)

 


      