Burgau |
SITE (OPERATOR) : Burgau (Landkreis Günzburg)
APPLICATION : incineration of Municipal waste and bulky refuse
BICARBONATE USED SINCE : January 1996
CAPACITY : 2 x 3 t/day (140 kt/yr, permission)
FLUE GAS CLEANING : pre-dedusting (cyclone filter), sodium bicarbonate injection, filtration (fabric filter), catalytic denox system
CONSTRUCTOR: Babcock Kraus-Maffei Industrieanlagen GmbH, Munich

PERFORMANCES
|
Parameter
|
Units
|
Characteristics of the flue gas before treatment
|
Limits to respect
|
Measured values
|
|
HCl
|
mg/Nm3 dry gases
|
400
|
10
|
< 9
|
|
SO2
|
mg/Nm3 dry gases
|
200
|
50
|
< 15
|
 |